環境溫度為25度,將規格為(厚0.10 \寬8mm\長100mm)的鎳片兩端接上可調直流電源,分別調節電源,使加載于鎳片上電流分別達到要求的電流值(如:5A、10A、15A、20A),各持續維持一段時間,按時間段分別測量鎳片各端點的溫度,最短持續通電60分鐘后、被測量鎳片的各點溫度應小于30度為可承載電流。
時間段分別測量鎳片各端點的溫度,最短持續通電60分鐘后、被測量鎳片的各點溫度應小于30度為可承載電流。
鎳片承載
|
檢測時間段
|
負極鎳片端℃
|
負極輸入端
|
連接鎳片
|
正極鎳片端
|
正極輸入端
|
電流A
|
(分鐘)
|
|
℃
|
℃
|
℃
|
℃
|
|
|
|
|
|
|
|
|
1
|
25.2
|
26.2
|
25.3
|
25.2
|
28.3
|
|
|
|
|
|
|
|
5
|
10
|
25.3
|
26.9
|
25.3
|
25.5
|
28.3
|
|
|
|
|
|
|
|
|
30
|
25.6
|
26.9
|
25.5
|
25.7
|
29.4
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
60
|
25.6
|
27.2
|
26.3
|
25.6
|
27.9
|
|
|
|
|
|
|
|
|
1
|
27.4
|
31.8
|
26.8
|
25.8
|
34.9
|
|
|
|
|
|
|
|
10
|
10
|
27.1
|
31.1
|
27.7
|
26.9
|
32.3
|
|
|
|
|
|
|
|
|
30
|
28.1
|
29.8
|
29.2
|
26.8
|
29.8
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
60
|
28.1
|
33.4
|
29.8
|
26.8
|
34.7
|
|
|
|
|
|
|
|
|
1
|
32.9
|
40.7
|
34.0
|
27.3
|
39.9
|
|
|
|
|
|
|
|
15
|
10
|
32.0
|
43.1
|
37.1
|
27.6
|
47.7
|
|
|
|
|
|
|
|
|
30
|
33.1
|
36.6
|
37.5
|
28.1
|
36.4
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
60
|
32.4
|
37.7
|
33.8
|
27.3
|
42.1
|
|
|
|
|
|
|
|
小結:厚0.10、寬8.0mm(橫截面積0.8m㎡)的鎳片可持續長時間通過10A直流;在通過15A時鎳片溫度有輕微上升現象,也就是說輕微過載;在通過20A時鎳片溫度有較快上升現象,也就是說嚴重過載﹒
|